Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated voltage
690 - 690V
Rated permanent current Iu
4000A
Integrated earth fault protection
No
Type of electrical connection of main circuit
Connection at separate chassis part
With switched-off indicator
Yes
Adjustment range short-term delayed short-circuit release
2400.0 - 40000A
Number of auxiliary contacts as change-over contact
4
Adjustment range undelayed short-circuit release
6000.0 - 60000A
DIN rail (top hat rail) mounting optional
No
Suitable for DIN rail (top hat rail) mounting
No
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Motor drive optional
Yes
Number of poles
3
Type of control element
Push button
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Yes
Degree of protection (IP)
IP30
Motor drive integrated
No
Overload release current setting
1600.0 - 4000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
1SDA072595R1 | E6.2V 4000 EKIP TOUCH LSI 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated voltage
690 .. 690V
Rated permanent current Iu
4000A
Integrated earth fault protection
Type of electrical connection of main circuit
Connection at separate chassis part
With switched-off indicator
Adjustment range short-term delayed short-circuit release
2400.0 .. 40000A
Number of auxiliary contacts as change-over contact
4
Adjustment range undelayed short-circuit release
6000.0 .. 60000A
DIN rail (top hat rail) mounting optional
Suitable for DIN rail (top hat rail) mounting
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Motor drive optional
Number of poles
3
Type of control element
Push button
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Degree of protection (IP)
IP30
Motor drive integrated
Overload release current setting
1600.0 .. 4000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA