Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Integrated earth fault protection
Yes
Rated voltage
690 - 690V
Suitable for DIN rail (top hat rail) mounting
No
With switched-off indicator
Yes
Overload release current setting
1600.0 - 4000A
DIN rail (top hat rail) mounting optional
No
With under voltage release
No
Rated permanent current Iu
4000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Type of control element
Push button
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
6000.0 - 60000A
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range short-term delayed short-circuit release
2400.0 - 40000A
Complete device with protection unit
Yes
Motor drive integrated
No
Degree of protection (IP)
IP30
Number of auxiliary contacts as change-over contact
4
Number of poles
3
Motor drive optional
Yes
Position of connection for main current circuit
Connection at separate chassis part
From same serie
1SDA072596R1 | E6.2V 4000 EKIP TOUCH LSIG 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Integrated earth fault protection
Rated voltage
690 .. 690V
Suitable for DIN rail (top hat rail) mounting
With switched-off indicator
Overload release current setting
1600.0 .. 4000A
DIN rail (top hat rail) mounting optional
With under voltage release
Rated permanent current Iu
4000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Type of control element
Push button
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
6000.0 .. 60000A
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range short-term delayed short-circuit release
2400.0 .. 40000A
Complete device with protection unit
Motor drive integrated
Degree of protection (IP)
IP30
Number of auxiliary contacts as change-over contact
4
Number of poles
3
Motor drive optional
Position of connection for main current circuit
Connection at separate chassis part
From same serie