Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
4000A
Rated voltage
690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Adjustment range short-term delayed short-circuit release
2400.0 - 40000A
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
No
Adjustment range undelayed short-circuit release
6000.0 - 60000A
Integrated earth fault protection
No
Number of auxiliary contacts as normally open contact
0
Number of poles
3
With switched-off indicator
Yes
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
1600.0 - 4000A
DIN rail (top hat rail) mounting optional
No
Degree of protection (IP)
IP30
Motor drive integrated
No
Motor drive optional
Yes
Complete device with protection unit
Yes
1SDA072598R1 | E6.2V 4000 EKIP HI-TOUCH LSI 3P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
4000A
Rated voltage
690 .. 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Adjustment range short-term delayed short-circuit release
2400.0 .. 40000A
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
Adjustment range undelayed short-circuit release
6000.0 .. 60000A
Integrated earth fault protection
Number of auxiliary contacts as normally open contact
0
Number of poles
3
With switched-off indicator
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
1600.0 .. 4000A
DIN rail (top hat rail) mounting optional
Degree of protection (IP)
IP30
Motor drive integrated
Motor drive optional
Complete device with protection unit