Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Overload release current setting
100.0 - 250A
Adjustment range undelayed short-circuit release
375.0 - 3750A
Rated permanent current Iu
250A
Integrated earth fault protection
No
Adjustment range short-term delayed short-circuit release
150.0 - 2500A
Rated voltage
690 - 690V
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
No
Suitable for DIN rail (top hat rail) mounting
No
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally open contact
0
With switched-off indicator
Yes
Type of electrical connection of main circuit
Connection at separate chassis part
Type of control element
Push button
Number of poles
4
Complete device with protection unit
Yes
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally closed contact
0
Motor drive integrated
No
Motor drive optional
Yes
Degree of protection (IP)
IP30
From same serie
1SDA072675R1 | E1.2N 250 EKIP TOUCH LSI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Overload release current setting
100.0 .. 250A
Adjustment range undelayed short-circuit release
375.0 .. 3750A
Rated permanent current Iu
250A
Integrated earth fault protection
Adjustment range short-term delayed short-circuit release
150.0 .. 2500A
Rated voltage
690 .. 690V
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
Suitable for DIN rail (top hat rail) mounting
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally open contact
0
With switched-off indicator
Type of electrical connection of main circuit
Connection at separate chassis part
Type of control element
Push button
Number of poles
4
Complete device with protection unit
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally closed contact
0
Motor drive integrated
Motor drive optional
Degree of protection (IP)
IP30
From same serie