Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
250A
Rated voltage
690 - 690V
Adjustment range short-term delayed short-circuit release
150.0 - 2500A
Overload release current setting
100.0 - 250A
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
375.0 - 3750A
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
Yes
Number of poles
4
Motor drive integrated
No
Complete device with protection unit
Yes
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Yes
Degree of protection (IP)
IP30
Type of control element
Push button
Suitable for DIN rail (top hat rail) mounting
No
Integrated earth fault protection
Yes
Device construction
Built-in device slide-in technique (withdrawable)
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
From same serie
1SDA072679R1 | E1.2N 250 EKIP HI-TOUCH LSIG 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
250A
Rated voltage
690 .. 690V
Adjustment range short-term delayed short-circuit release
150.0 .. 2500A
Overload release current setting
100.0 .. 250A
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
375.0 .. 3750A
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
With switched-off indicator
Number of poles
4
Motor drive integrated
Complete device with protection unit
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Degree of protection (IP)
IP30
Type of control element
Push button
Suitable for DIN rail (top hat rail) mounting
Integrated earth fault protection
Device construction
Built-in device slide-in technique (withdrawable)
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA