Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
630A
Adjustment range short-term delayed short-circuit release
378.0 - 6300A
Adjustment range undelayed short-circuit release
945.0 - 9450A
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 - 690V
Device construction
Built-in device slide-in technique (withdrawable)
Integrated earth fault protection
Yes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Number of auxiliary contacts as normally closed contact
0
Complete device with protection unit
Yes
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
Overload release current setting
252.0 - 630A
Motor drive integrated
No
Degree of protection (IP)
IP30
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
No
Suitable for DIN rail (top hat rail) mounting
No
Type of control element
Push button
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Yes
With switched-off indicator
Yes
From same serie
1SDA072689R1 | E1.2B 630 EKIP HI-TOUCH LSIG 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
630A
Adjustment range short-term delayed short-circuit release
378.0 .. 6300A
Adjustment range undelayed short-circuit release
945.0 .. 9450A
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 .. 690V
Device construction
Built-in device slide-in technique (withdrawable)
Integrated earth fault protection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Number of auxiliary contacts as normally closed contact
0
Complete device with protection unit
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
Overload release current setting
252.0 .. 630A
Motor drive integrated
Degree of protection (IP)
IP30
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
Suitable for DIN rail (top hat rail) mounting
Type of control element
Push button
Number of auxiliary contacts as change-over contact
4