Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 - 690V
Adjustment range short-term delayed short-circuit release
378.0 - 6300A
Adjustment range undelayed short-circuit release
945.0 - 9450A
Type of electrical connection of main circuit
Connection at separate chassis part
Rated permanent current Iu
630A
DIN rail (top hat rail) mounting optional
No
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
No
With switched-off indicator
Yes
Number of poles
4
Motor drive integrated
No
Number of auxiliary contacts as change-over contact
4
Type of control element
Push button
Complete device with protection unit
Yes
Overload release current setting
252.0 - 630A
With under voltage release
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Motor drive optional
Yes
Integrated earth fault protection
No
Position of connection for main current circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
From same serie
1SDA072698R1 | E1.2C 630 EKIP HI-TOUCH LSI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 .. 690V
Adjustment range short-term delayed short-circuit release
378.0 .. 6300A
Adjustment range undelayed short-circuit release
945.0 .. 9450A
Type of electrical connection of main circuit
Connection at separate chassis part
Rated permanent current Iu
630A
DIN rail (top hat rail) mounting optional
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
With switched-off indicator
Number of poles
4
Motor drive integrated
Number of auxiliary contacts as change-over contact
4
Type of control element
Push button
Complete device with protection unit
Overload release current setting
252.0 .. 630A
With under voltage release
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Motor drive optional
Integrated earth fault protection
Position of connection for main current circuit
Connection at separate chassis part
Degree of protection (IP)
IP30