Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
No
Integrated earth fault protection
No
Rated permanent current Iu
630A
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as change-over contact
4
Rated voltage
690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
With switched-off indicator
Yes
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Yes
Degree of protection (IP)
IP30
Overload release current setting
252.0 - 630A
With under voltage release
No
Number of poles
4
Motor drive integrated
No
Motor drive optional
Yes
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range undelayed short-circuit release
945.0 - 9450A
From same serie
1SDA072704R1 | E1.2N 630 EKIP TOUCH LI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
Integrated earth fault protection
Rated permanent current Iu
630A
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as change-over contact
4
Rated voltage
690 .. 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
With switched-off indicator
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Degree of protection (IP)
IP30
Overload release current setting
252.0 .. 630A
With under voltage release
Number of poles
4
Motor drive integrated
Motor drive optional
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range undelayed short-circuit release
945.0 .. 9450A
From same serie