Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Adjustment range undelayed short-circuit release
945.0 - 9450A
Type of electrical connection of main circuit
Connection at separate chassis part
Rated voltage
690 - 690V
Rated permanent current Iu
630A
Integrated earth fault protection
Yes
DIN rail (top hat rail) mounting optional
No
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
No
Adjustment range short-term delayed short-circuit release
378.0 - 6300A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Number of auxiliary contacts as normally open contact
0
Overload release current setting
252.0 - 630A
Number of auxiliary contacts as normally closed contact
0
Type of control element
Push button
Number of poles
4
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Yes
Motor drive optional
Yes
Motor drive integrated
No
With switched-off indicator
Yes
Degree of protection (IP)
IP30
Number of auxiliary contacts as change-over contact
4
From same serie
1SDA072706R1 | E1.2N 630 EKIP TOUCH LSIG 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Adjustment range undelayed short-circuit release
945.0 .. 9450A
Type of electrical connection of main circuit
Connection at separate chassis part
Rated voltage
690 .. 690V
Rated permanent current Iu
630A
Integrated earth fault protection
DIN rail (top hat rail) mounting optional
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
Adjustment range short-term delayed short-circuit release
378.0 .. 6300A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Number of auxiliary contacts as normally open contact
0
Overload release current setting
252.0 .. 630A
Number of auxiliary contacts as normally closed contact
0
Type of control element
Push button
Number of poles
4
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Motor drive optional
Motor drive integrated
With switched-off indicator
Degree of protection (IP)
IP30
Number of auxiliary contacts as change-over contact
4