Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 - 690V
Rated permanent current Iu
800A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally closed contact
0
Suitable for DIN rail (top hat rail) mounting
No
Integrated earth fault protection
No
Overload release current setting
320.0 - 800A
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
1200.0 - 12000A
With switched-off indicator
Yes
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
No
Number of poles
4
Degree of protection (IP)
IP30
Number of auxiliary contacts as change-over contact
4
Type of control element
Push button
Motor drive optional
Yes
Complete device with protection unit
Yes
Position of connection for main current circuit
Connection at separate chassis part
From same serie
1SDA072731R1 | E1.2C 800 EKIP DIP LI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 .. 690V
Rated permanent current Iu
800A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally closed contact
0
Suitable for DIN rail (top hat rail) mounting
Integrated earth fault protection
Overload release current setting
320.0 .. 800A
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
1200.0 .. 12000A
With switched-off indicator
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
Number of poles
4
Degree of protection (IP)
IP30
Number of auxiliary contacts as change-over contact
4
Type of control element
Push button
Motor drive optional
Complete device with protection unit
Position of connection for main current circuit
Connection at separate chassis part
From same serie