

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
800A
Rated voltage
690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Adjustment range undelayed short-circuit release
1200.0 - 12000A
Overload release current setting
320.0 - 800A
Integrated earth fault protection
No
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Device construction
Built-in device slide-in technique (withdrawable)
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Yes
Type of control element
Push button
With under voltage release
No
Number of poles
4
Motor drive optional
Yes
Degree of protection (IP)
IP30
Motor drive integrated
No
Complete device with protection unit
Yes
From same serie
1SDA072744R1 | E1.2N 800 EKIP TOUCH LI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
800A
Rated voltage
690 .. 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Adjustment range undelayed short-circuit release
1200.0 .. 12000A
Overload release current setting
320.0 .. 800A
Integrated earth fault protection
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Device construction
Built-in device slide-in technique (withdrawable)
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Type of control element
Push button
With under voltage release
Number of poles
4
Motor drive optional
Degree of protection (IP)
IP30
Motor drive integrated
Complete device with protection unit
From same serie
We use cookies to enhance your experience.