Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Adjustment range short-term delayed short-circuit release
600.0 - 10000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Adjustment range undelayed short-circuit release
1500.0 - 15000A
Rated permanent current Iu
1000A
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally closed contact
0
Type of control element
Push button
Integrated earth fault protection
No
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
No
Motor drive optional
Yes
With switched-off indicator
Yes
Degree of protection (IP)
IP30
Rated voltage
690 - 690V
Motor drive integrated
No
Complete device with protection unit
Yes
Overload release current setting
400.0 - 1000A
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
From same serie
1SDA072775R1 | E1.2C 1000 EKIP TOUCH LSI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Adjustment range short-term delayed short-circuit release
600.0 .. 10000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
Rated permanent current Iu
1000A
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally closed contact
0
Type of control element
Push button
Integrated earth fault protection
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
Motor drive optional
With switched-off indicator
Degree of protection (IP)
IP30
Rated voltage
690 .. 690V
Motor drive integrated
Complete device with protection unit
Overload release current setting
400.0 .. 1000A
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
From same serie