Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Overload release current setting
400.0 - 1000A
Adjustment range short-term delayed short-circuit release
600.0 - 10000A
Device construction
Built-in device slide-in technique (withdrawable)
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Rated voltage
690 - 690V
Suitable for DIN rail (top hat rail) mounting
No
Rated permanent current Iu
1000A
DIN rail (top hat rail) mounting optional
No
Adjustment range undelayed short-circuit release
1500.0 - 15000A
Type of electrical connection of main circuit
Connection at separate chassis part
Number of poles
4
Number of auxiliary contacts as change-over contact
4
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally closed contact
0
Type of control element
Push button
Integrated earth fault protection
Yes
With switched-off indicator
Yes
Complete device with protection unit
Yes
Motor drive integrated
No
Number of auxiliary contacts as normally open contact
0
Motor drive optional
Yes
Degree of protection (IP)
IP30
From same serie
1SDA072777R1 | E1.2C 1000 EKIP G TOUCH LSIG 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Overload release current setting
400.0 .. 1000A
Adjustment range short-term delayed short-circuit release
600.0 .. 10000A
Device construction
Built-in device slide-in technique (withdrawable)
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
50kA
Rated voltage
690 .. 690V
Suitable for DIN rail (top hat rail) mounting
Rated permanent current Iu
1000A
DIN rail (top hat rail) mounting optional
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
Type of electrical connection of main circuit
Connection at separate chassis part
Number of poles
4
Number of auxiliary contacts as change-over contact
4
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally closed contact
0
Type of control element
Push button
Integrated earth fault protection
With switched-off indicator
Complete device with protection unit
Motor drive integrated
Number of auxiliary contacts as normally open contact
0
Motor drive optional
Degree of protection (IP)
IP30