Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Integrated earth fault protection
Yes
Rated permanent current Iu
1000A
Number of auxiliary contacts as normally open contact
0
Device construction
Built-in device slide-in technique (withdrawable)
Position of connection for main current circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
1500.0 - 15000A
With switched-off indicator
Yes
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as normally closed contact
0
Motor drive integrated
No
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Yes
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
Adjustment range short-term delayed short-circuit release
600.0 - 10000A
Suitable for DIN rail (top hat rail) mounting
No
Number of poles
4
Overload release current setting
400.0 - 1000A
Rated voltage
690 - 690V
Type of control element
Push button
DIN rail (top hat rail) mounting optional
No
From same serie
1SDA072787R1 | E1.2N 1000 EKIP G TOUCH LSIG 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Integrated earth fault protection
Rated permanent current Iu
1000A
Number of auxiliary contacts as normally open contact
0
Device construction
Built-in device slide-in technique (withdrawable)
Position of connection for main current circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
With switched-off indicator
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as normally closed contact
0
Motor drive integrated
Number of auxiliary contacts as change-over contact
4
Motor drive optional
Degree of protection (IP)
IP30
Complete device with protection unit
Adjustment range short-term delayed short-circuit release
600.0 .. 10000A
Suitable for DIN rail (top hat rail) mounting
Number of poles
4
Overload release current setting
400.0 .. 1000A
Rated voltage
690 .. 690V
Type of control element
Push button
DIN rail (top hat rail) mounting optional
From same serie
We use cookies to enhance your experience.