Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Type of electrical connection of main circuit
Connection at separate chassis part
Number of poles
4
Suitable for DIN rail (top hat rail) mounting
No
Integrated earth fault protection
No
Motor drive optional
Yes
DIN rail (top hat rail) mounting optional
No
Adjustment range undelayed short-circuit release
1875.0 - 18750A
Overload release current setting
500.0 - 1250A
Complete device with protection unit
Yes
With under voltage release
No
Device construction
Built-in device slide-in technique (withdrawable)
With switched-off indicator
Yes
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
No
Rated voltage
690 - 690V
Degree of protection (IP)
IP30
From same serie
1SDA072804R1 | E1.2B 1250 EKIP TOUCH LI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1250A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Type of electrical connection of main circuit
Connection at separate chassis part
Number of poles
4
Suitable for DIN rail (top hat rail) mounting
Integrated earth fault protection
Motor drive optional
DIN rail (top hat rail) mounting optional
Adjustment range undelayed short-circuit release
1875.0 .. 18750A
Overload release current setting
500.0 .. 1250A
Complete device with protection unit
With under voltage release
Device construction
Built-in device slide-in technique (withdrawable)
With switched-off indicator
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
Rated voltage
690 .. 690V
Degree of protection (IP)
IP30
From same serie