Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Overload release current setting
640.0 - 1600A
Rated permanent current Iu
1600A
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Type of electrical connection of main circuit
Connection at separate chassis part
Rated voltage
690 - 690V
Integrated earth fault protection
No
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range short-term delayed short-circuit release
960.0 - 16000A
With switched-off indicator
Yes
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Number of poles
4
Motor drive integrated
No
Type of control element
Push button
Motor drive optional
Yes
Complete device with protection unit
Yes
Position of connection for main current circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
From same serie
1SDA072845R1 | E1.2B 1600 EKIP TOUCH LSI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Overload release current setting
640.0 .. 1600A
Rated permanent current Iu
1600A
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Type of electrical connection of main circuit
Connection at separate chassis part
Rated voltage
690 .. 690V
Integrated earth fault protection
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range short-term delayed short-circuit release
960.0 .. 16000A
With switched-off indicator
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Number of poles
4
Motor drive integrated
Type of control element
Push button
Motor drive optional
Complete device with protection unit
Position of connection for main current circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
From same serie