Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Adjustment range undelayed short-circuit release
1200.0 - 12000A
Integrated earth fault protection
Yes
Adjustment range short-term delayed short-circuit release
480.0 - 8000A
DIN rail (top hat rail) mounting optional
No
Type of electrical connection of main circuit
Connection at separate chassis part
Rated voltage
690 - 690V
With switched-off indicator
Yes
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Overload release current setting
320.0 - 800A
Degree of protection (IP)
IP30
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
Type of control element
Push button
Motor drive optional
Yes
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
800A
Motor drive integrated
No
Complete device with protection unit
Yes
From same serie
1SDA072877R1 | E2.2N 800 EKIP G TOUCH LSIG 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Adjustment range undelayed short-circuit release
1200.0 .. 12000A
Integrated earth fault protection
Adjustment range short-term delayed short-circuit release
480.0 .. 8000A
DIN rail (top hat rail) mounting optional
Type of electrical connection of main circuit
Connection at separate chassis part
Rated voltage
690 .. 690V
With switched-off indicator
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as change-over contact
4
Overload release current setting
320.0 .. 800A
Degree of protection (IP)
IP30
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
Type of control element
Push button
Motor drive optional
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
800A
Motor drive integrated
Complete device with protection unit