Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Suitable for DIN rail (top hat rail) mounting
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Integrated earth fault protection
No
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 - 690V
Number of auxiliary contacts as change-over contact
4
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
400.0 - 1000A
Number of poles
4
With switched-off indicator
Yes
Rated permanent current Iu
1000A
Degree of protection (IP)
IP30
Motor drive optional
Yes
DIN rail (top hat rail) mounting optional
No
Motor drive integrated
No
Adjustment range undelayed short-circuit release
1500.0 - 15000A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Yes
Type of control element
Push button
From same serie
1SDA072904R1 | E2.2N 1000 EKIP TOUCH LI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Suitable for DIN rail (top hat rail) mounting
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Integrated earth fault protection
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 .. 690V
Number of auxiliary contacts as change-over contact
4
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
400.0 .. 1000A
Number of poles
4
With switched-off indicator
Rated permanent current Iu
1000A
Degree of protection (IP)
IP30
Motor drive optional
DIN rail (top hat rail) mounting optional
Motor drive integrated
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Position of connection for main current circuit
Connection at separate chassis part
Complete device with protection unit
Type of control element
Push button