Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
1000A
Adjustment range undelayed short-circuit release
1500.0 - 15000A
With switched-off indicator
Yes
Type of electrical connection of main circuit
Connection at separate chassis part
Rated voltage
690 - 690V
Number of auxiliary contacts as normally open contact
0
Overload release current setting
400.0 - 1000A
Device construction
Built-in device slide-in technique (withdrawable)
Number of poles
4
Suitable for DIN rail (top hat rail) mounting
No
Integrated earth fault protection
Yes
Number of auxiliary contacts as normally closed contact
0
Complete device with protection unit
Yes
DIN rail (top hat rail) mounting optional
No
Adjustment range short-term delayed short-circuit release
600.0 - 10000A
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
No
Type of control element
Push button
Motor drive optional
Yes
Number of auxiliary contacts as change-over contact
4
Degree of protection (IP)
IP30
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
From same serie
1SDA072913R1 | E2.2S 1000 EKIP DIP LSIG 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
1000A
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
With switched-off indicator
Type of electrical connection of main circuit
Connection at separate chassis part
Rated voltage
690 .. 690V
Number of auxiliary contacts as normally open contact
0
Overload release current setting
400.0 .. 1000A
Device construction
Built-in device slide-in technique (withdrawable)
Number of poles
4
Suitable for DIN rail (top hat rail) mounting
Integrated earth fault protection
Number of auxiliary contacts as normally closed contact
0
Complete device with protection unit
DIN rail (top hat rail) mounting optional
Adjustment range short-term delayed short-circuit release
600.0 .. 10000A
Position of connection for main current circuit
Connection at separate chassis part
Motor drive integrated
Type of control element
Push button
Motor drive optional
Number of auxiliary contacts as change-over contact
4
Degree of protection (IP)
IP30
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA