Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
DIN rail (top hat rail) mounting optional
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Rated permanent current Iu
1000A
Degree of protection (IP)
IP30
Motor drive integrated
No
With under voltage release
No
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 - 690V
Adjustment range short-term delayed short-circuit release
600.0 - 10000A
Integrated earth fault protection
Yes
Number of auxiliary contacts as change-over contact
4
Type of electrical connection of main circuit
Connection at separate chassis part
Type of control element
Push button
Complete device with protection unit
Yes
Adjustment range undelayed short-circuit release
1500.0 - 15000A
With switched-off indicator
Yes
Overload release current setting
400.0 - 1000A
Number of poles
4
Motor drive optional
Yes
Suitable for DIN rail (top hat rail) mounting
No
Position of connection for main current circuit
Connection at separate chassis part
From same serie
1SDA072916R1 | E2.2S 1000 EKIP TOUCH LSIG 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
DIN rail (top hat rail) mounting optional
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Rated permanent current Iu
1000A
Degree of protection (IP)
IP30
Motor drive integrated
With under voltage release
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 .. 690V
Adjustment range short-term delayed short-circuit release
600.0 .. 10000A
Integrated earth fault protection
Number of auxiliary contacts as change-over contact
4
Type of electrical connection of main circuit
Connection at separate chassis part
Type of control element
Push button
Complete device with protection unit
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
With switched-off indicator
Overload release current setting
400.0 .. 1000A
Number of poles
4
Motor drive optional
Suitable for DIN rail (top hat rail) mounting
Position of connection for main current circuit
Connection at separate chassis part
From same serie