Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1000A
DIN rail (top hat rail) mounting optional
No
With under voltage release
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Suitable for DIN rail (top hat rail) mounting
No
Device construction
Built-in device slide-in technique (withdrawable)
Overload release current setting
400.0 - 1000A
Number of poles
4
Adjustment range undelayed short-circuit release
1500.0 - 15000A
Adjustment range short-term delayed short-circuit release
600.0 - 10000A
Number of auxiliary contacts as change-over contact
4
Integrated earth fault protection
No
Rated voltage
690 - 690V
Degree of protection (IP)
IP30
Type of electrical connection of main circuit
Connection at separate chassis part
Motor drive integrated
No
With switched-off indicator
Yes
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Yes
Type of control element
Push button
Complete device with protection unit
Yes
1SDA072928R1 | E2.2H 1000 EKIP HI-TOUCH LSI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
1000A
DIN rail (top hat rail) mounting optional
With under voltage release
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Suitable for DIN rail (top hat rail) mounting
Device construction
Built-in device slide-in technique (withdrawable)
Overload release current setting
400.0 .. 1000A
Number of poles
4
Adjustment range undelayed short-circuit release
1500.0 .. 15000A
Adjustment range short-term delayed short-circuit release
600.0 .. 10000A
Number of auxiliary contacts as change-over contact
4
Integrated earth fault protection
Rated voltage
690 .. 690V
Degree of protection (IP)
IP30
Type of electrical connection of main circuit
Connection at separate chassis part
Motor drive integrated
With switched-off indicator
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Type of control element
Push button
Complete device with protection unit