Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Type of electrical connection of main circuit
Connection at separate chassis part
Rated permanent current Iu
1600A
Rated voltage
690 - 690V
Number of auxiliary contacts as normally open contact
0
Integrated earth fault protection
No
Number of auxiliary contacts as change-over contact
4
Adjustment range short-term delayed short-circuit release
960.0 - 16000A
Suitable for DIN rail (top hat rail) mounting
No
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
No
Type of control element
Push button
With switched-off indicator
Yes
Number of poles
4
Motor drive integrated
No
Complete device with protection unit
Yes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Overload release current setting
640.0 - 1600A
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Motor drive optional
Yes
Degree of protection (IP)
IP30
1SDA072965R1 | E2.2B 1600 EKIP TOUCH LSI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Type of electrical connection of main circuit
Connection at separate chassis part
Rated permanent current Iu
1600A
Rated voltage
690 .. 690V
Number of auxiliary contacts as normally open contact
0
Integrated earth fault protection
Number of auxiliary contacts as change-over contact
4
Adjustment range short-term delayed short-circuit release
960.0 .. 16000A
Suitable for DIN rail (top hat rail) mounting
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
Type of control element
Push button
With switched-off indicator
Number of poles
4
Motor drive integrated
Complete device with protection unit
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
42kA
Overload release current setting
640.0 .. 1600A
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Motor drive optional
Degree of protection (IP)
IP30