Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
1600A
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Device construction
Built-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
640.0 - 1600A
Number of auxiliary contacts as change-over contact
4
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Yes
Complete device with protection unit
Yes
Motor drive integrated
No
Motor drive optional
Yes
Type of control element
Push button
Adjustment range short-term delayed short-circuit release
960.0 - 16000A
Rated voltage
690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Degree of protection (IP)
IP30
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
No
Suitable for DIN rail (top hat rail) mounting
No
Number of poles
4
From same serie
1SDA072975R1 | E2.2N 1600 EKIP TOUCH LSI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
1600A
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Device construction
Built-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
640.0 .. 1600A
Number of auxiliary contacts as change-over contact
4
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Complete device with protection unit
Motor drive integrated
Motor drive optional
Type of control element
Push button
Adjustment range short-term delayed short-circuit release
960.0 .. 16000A
Rated voltage
690 .. 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Degree of protection (IP)
IP30
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Suitable for DIN rail (top hat rail) mounting
Number of poles
4