Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
1600A
Rated voltage
690 - 690V
Adjustment range short-term delayed short-circuit release
960.0 - 16000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Overload release current setting
640.0 - 1600A
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
No
Adjustment range undelayed short-circuit release
2400.0 - 24000A
Number of poles
4
With switched-off indicator
Yes
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
No
Position of connection for main current circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
No
Complete device with protection unit
Yes
Motor drive optional
Yes
Degree of protection (IP)
IP30
Type of control element
Push button
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Yes
1SDA072990R1 | E2.2S 1600 EKIP G HI-TOUCH LSIG 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
1600A
Rated voltage
690 .. 690V
Adjustment range short-term delayed short-circuit release
960.0 .. 16000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Overload release current setting
640.0 .. 1600A
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
Adjustment range undelayed short-circuit release
2400.0 .. 24000A
Number of poles
4
With switched-off indicator
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
Position of connection for main current circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
Complete device with protection unit
Motor drive optional
Degree of protection (IP)
IP30
Type of control element
Push button
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
We use cookies to enhance your experience.