Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
2000A
Rated voltage
690 - 690V
Adjustment range short-term delayed short-circuit release
1200.0 - 20000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Overload release current setting
800.0 - 2000A
Integrated earth fault protection
Yes
Adjustment range undelayed short-circuit release
3000.0 - 30000A
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
With switched-off indicator
Yes
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
Type of control element
Push button
Number of auxiliary contacts as change-over contact
4
Degree of protection (IP)
IP30
Motor drive optional
Yes
Complete device with protection unit
Yes
Motor drive integrated
No
DIN rail (top hat rail) mounting optional
No
1SDA073037R1 | E2.2H 2000 EKIP G TOUCH LSIG 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
2000A
Rated voltage
690 .. 690V
Adjustment range short-term delayed short-circuit release
1200.0 .. 20000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Overload release current setting
800.0 .. 2000A
Integrated earth fault protection
Adjustment range undelayed short-circuit release
3000.0 .. 30000A
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
With switched-off indicator
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
Type of control element
Push button
Number of auxiliary contacts as change-over contact
4
Degree of protection (IP)
IP30
Motor drive optional
Complete device with protection unit
Motor drive integrated
DIN rail (top hat rail) mounting optional
We use cookies to enhance your experience.