Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Adjustment range undelayed short-circuit release
3000.0 - 30000A
Rated permanent current Iu
2000A
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
No
Type of control element
Push button
Complete device with protection unit
Yes
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as change-over contact
4
Overload release current setting
800.0 - 2000A
With under voltage release
No
Adjustment range short-term delayed short-circuit release
1200.0 - 20000A
Position of connection for main current circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
No
With switched-off indicator
Yes
Number of poles
4
Motor drive integrated
No
Motor drive optional
Yes
Degree of protection (IP)
IP30
1SDA073038R1 | E2.2H 2000 EKIP HI-TOUCH LSI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated voltage
690 .. 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Adjustment range undelayed short-circuit release
3000.0 .. 30000A
Rated permanent current Iu
2000A
Type of electrical connection of main circuit
Connection at separate chassis part
Integrated earth fault protection
Type of control element
Push button
Complete device with protection unit
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as change-over contact
4
Overload release current setting
800.0 .. 2000A
With under voltage release
Adjustment range short-term delayed short-circuit release
1200.0 .. 20000A
Position of connection for main current circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
With switched-off indicator
Number of poles
4
Motor drive integrated
Motor drive optional
Degree of protection (IP)
IP30