Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
2500A
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as change-over contact
4
Complete device with protection unit
Yes
With switched-off indicator
Yes
Adjustment range short-term delayed short-circuit release
1500.0 - 25000A
Suitable for DIN rail (top hat rail) mounting
No
Rated voltage
690 - 690V
Type of electrical connection of main circuit
Connection at separate chassis part
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range undelayed short-circuit release
3750.0 - 37500A
Integrated earth fault protection
No
Overload release current setting
1000.0 - 2500A
Number of poles
4
With under voltage release
No
Degree of protection (IP)
IP30
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Yes
Motor drive integrated
No
From same serie
1SDA073068R1 | E2.2H 2500 EKIP HI-TOUCH LSI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
2500A
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as change-over contact
4
Complete device with protection unit
With switched-off indicator
Adjustment range short-term delayed short-circuit release
1500.0 .. 25000A
Suitable for DIN rail (top hat rail) mounting
Rated voltage
690 .. 690V
Type of electrical connection of main circuit
Connection at separate chassis part
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Device construction
Built-in device slide-in technique (withdrawable)
Adjustment range undelayed short-circuit release
3750.0 .. 37500A
Integrated earth fault protection
Overload release current setting
1000.0 .. 2500A
Number of poles
4
With under voltage release
Degree of protection (IP)
IP30
Type of control element
Push button
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Motor drive integrated