Technical specifications

Overload release current setting1000.0 - 2500A
Rated permanent current Iu2500A
Rated voltage690 - 690V
Motor drive integratedNo
Number of auxiliary contacts as normally closed contact0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100kA
Number of auxiliary contacts as normally open contact0
Motor drive optionalYes
Number of poles4
Suitable for DIN rail (top hat rail) mountingNo
Position of connection for main current circuitConnection at separate chassis part
Type of electrical connection of main circuitConnection at separate chassis part
Adjustment range short-term delayed short-circuit release1500.0 - 25000A
Integrated earth fault protectionYes
With switched-off indicatorYes
Type of control elementPush button
Adjustment range undelayed short-circuit release3750.0 - 37500A
Number of auxiliary contacts as change-over contact4
Degree of protection (IP)IP30
With integrated under voltage releaseNo
Device constructionBuilt-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA073069R1 | E2.2H 2500 EKIP HI-TOUCH LSIG 4P WMP

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Overload release current setting

1000.0 .. 2500A

Rated permanent current Iu

2500A

Rated voltage

690 .. 690V

Motor drive integrated

Number of auxiliary contacts as normally closed contact

0

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

Number of auxiliary contacts as normally open contact

0

Motor drive optional

Number of poles

4

Suitable for DIN rail (top hat rail) mounting

Position of connection for main current circuit

Connection at separate chassis part

Type of electrical connection of main circuit

Connection at separate chassis part

Adjustment range short-term delayed short-circuit release

1500.0 .. 25000A

Integrated earth fault protection

With switched-off indicator

Type of control element

Push button

Adjustment range undelayed short-circuit release

3750.0 .. 37500A

Number of auxiliary contacts as change-over contact

4

Degree of protection (IP)

IP30

With integrated under voltage release

Device construction

Built-in device slide-in technique (withdrawable)

DIN rail (top hat rail) mounting optional

Complete device with protection unit

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.