Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
2000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Rated voltage
690 - 690V
Adjustment range short-term delayed short-circuit release
1200.0 - 20000A
Adjustment range undelayed short-circuit release
3000.0 - 30000A
Overload release current setting
800.0 - 2000A
Integrated earth fault protection
Yes
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as change-over contact
4
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
Number of poles
4
With switched-off indicator
Yes
Type of control element
Push button
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
Motor drive optional
Yes
Motor drive integrated
No
From same serie
1SDA073083R1 | E4.2V 2000 EKIP DIP LSIG 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
2000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Rated voltage
690 .. 690V
Adjustment range short-term delayed short-circuit release
1200.0 .. 20000A
Adjustment range undelayed short-circuit release
3000.0 .. 30000A
Overload release current setting
800.0 .. 2000A
Integrated earth fault protection
Device construction
Built-in device slide-in technique (withdrawable)
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as change-over contact
4
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
Number of poles
4
With switched-off indicator
Type of control element
Push button
Degree of protection (IP)
IP30
Complete device with protection unit
Motor drive optional
Motor drive integrated
From same serie