Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
2000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Overload release current setting
800.0 - 2000A
Integrated earth fault protection
No
Suitable for DIN rail (top hat rail) mounting
No
Rated voltage
690 - 690V
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
No
Adjustment range undelayed short-circuit release
3000.0 - 30000A
Device construction
Built-in device slide-in technique (withdrawable)
With switched-off indicator
Yes
With under voltage release
No
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Number of auxiliary contacts as change-over contact
4
Complete device with protection unit
Yes
Motor drive optional
Yes
Motor drive integrated
No
Degree of protection (IP)
IP30
Number of poles
4
From same serie
1SDA073084R1 | E4.2V 2000 EKIP TOUCH LI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
2000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Overload release current setting
800.0 .. 2000A
Integrated earth fault protection
Suitable for DIN rail (top hat rail) mounting
Rated voltage
690 .. 690V
Type of electrical connection of main circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
Adjustment range undelayed short-circuit release
3000.0 .. 30000A
Device construction
Built-in device slide-in technique (withdrawable)
With switched-off indicator
With under voltage release
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Number of auxiliary contacts as change-over contact
4
Complete device with protection unit
Motor drive optional
Motor drive integrated
Degree of protection (IP)
IP30
Number of poles
4
From same serie