Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Integrated earth fault protection
No
Overload release current setting
800.0 - 2000A
Suitable for DIN rail (top hat rail) mounting
No
Rated voltage
690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Rated permanent current Iu
2000A
Type of electrical connection of main circuit
Connection at separate chassis part
With switched-off indicator
Yes
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
Type of control element
Push button
Number of auxiliary contacts as change-over contact
4
Adjustment range short-term delayed short-circuit release
1200.0 - 20000A
Complete device with protection unit
Yes
Adjustment range undelayed short-circuit release
3000.0 - 30000A
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
No
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
No
Motor drive optional
Yes
Degree of protection (IP)
IP30
From same serie
1SDA073088R1 | E4.2V 2000 EKIP HI-TOUCH LSI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Integrated earth fault protection
Overload release current setting
800.0 .. 2000A
Suitable for DIN rail (top hat rail) mounting
Rated voltage
690 .. 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Rated permanent current Iu
2000A
Type of electrical connection of main circuit
Connection at separate chassis part
With switched-off indicator
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
Type of control element
Push button
Number of auxiliary contacts as change-over contact
4
Adjustment range short-term delayed short-circuit release
1200.0 .. 20000A
Complete device with protection unit
Adjustment range undelayed short-circuit release
3000.0 .. 30000A
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally open contact
0
Motor drive integrated
Motor drive optional
Degree of protection (IP)
IP30
From same serie