- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
2500A
Overload release current setting
1000.0 - 2500A
Integrated earth fault protection
No
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Rated voltage
690 - 690V
Adjustment range short-term delayed short-circuit release
1500.0 - 25000A
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
No
Number of poles
4
DIN rail (top hat rail) mounting optional
No
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Adjustment range undelayed short-circuit release
3750.0 - 37500A
Number of auxiliary contacts as change-over contact
4
Type of electrical connection of main circuit
Connection at separate chassis part
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
With switched-off indicator
Yes
Complete device with protection unit
Yes
Motor drive integrated
No
Degree of protection (IP)
IP30
Motor drive optional
Yes
1SDA073102R1 | E4.2V 2500 EKIP DIP LSI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
2500A
Overload release current setting
1000.0 .. 2500A
Integrated earth fault protection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Rated voltage
690 .. 690V
Adjustment range short-term delayed short-circuit release
1500.0 .. 25000A
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
Number of poles
4
DIN rail (top hat rail) mounting optional
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as normally closed contact
0
Adjustment range undelayed short-circuit release
3750.0 .. 37500A
Number of auxiliary contacts as change-over contact
4
Type of electrical connection of main circuit
Connection at separate chassis part
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
With switched-off indicator
Complete device with protection unit
Motor drive integrated
Degree of protection (IP)
IP30
Motor drive optional