  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage release

No

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

66kA

Rated voltage

690 - 690V

Overload release current setting

1280.0 - 3200A

Rated permanent current Iu

3200A

Integrated earth fault protection

Yes

Type of electrical connection of main circuit

Connection at separate chassis part

Device construction

Built-in device slide-in technique (withdrawable)

Adjustment range undelayed short-circuit release

4800.0 - 48000A

Position of connection for main current circuit

Connection at separate chassis part

Adjustment range short-term delayed short-circuit release

1920.0 - 32000A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

4

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

No

Suitable for DIN rail (top hat rail) mounting

No

Motor drive optional

Yes

With switched-off indicator

Yes

Number of poles

4

Type of control element

Push button

Complete device with protection unit

Yes

Motor drive integrated

No

Degree of protection (IP)

IP30

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

1SDA073123R1 | E4.2N 3200 EKIP DIP LSIG 4P WMP

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage release

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

66kA

Rated voltage

690 .. 690V

Overload release current setting

1280.0 .. 3200A

Rated permanent current Iu

3200A

Integrated earth fault protection

Type of electrical connection of main circuit

Connection at separate chassis part

Device construction

Built-in device slide-in technique (withdrawable)

Adjustment range undelayed short-circuit release

4800.0 .. 48000A

Position of connection for main current circuit

Connection at separate chassis part

Adjustment range short-term delayed short-circuit release

1920.0 .. 32000A

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

4

Number of auxiliary contacts as normally closed contact

0

DIN rail (top hat rail) mounting optional

Suitable for DIN rail (top hat rail) mounting

Motor drive optional

With switched-off indicator

Number of poles

4

Type of control element

Push button

Complete device with protection unit

Motor drive integrated

Degree of protection (IP)

IP30