Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
3200A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Rated voltage
690 - 690V
Adjustment range short-term delayed short-circuit release
1920.0 - 32000A
Adjustment range undelayed short-circuit release
4800.0 - 48000A
Integrated earth fault protection
No
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as change-over contact
4
Overload release current setting
1280.0 - 3200A
With switched-off indicator
Yes
DIN rail (top hat rail) mounting optional
No
Degree of protection (IP)
IP30
Number of poles
4
Complete device with protection unit
Yes
Position of connection for main current circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Motor drive integrated
No
Type of control element
Push button
With under voltage release
No
Motor drive optional
Yes
From same serie
1SDA073132R1 | E4.2S 3200 EKIP DIP LSI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated permanent current Iu
3200A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
85kA
Rated voltage
690 .. 690V
Adjustment range short-term delayed short-circuit release
1920.0 .. 32000A
Adjustment range undelayed short-circuit release
4800.0 .. 48000A
Integrated earth fault protection
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as change-over contact
4
Overload release current setting
1280.0 .. 3200A
With switched-off indicator
DIN rail (top hat rail) mounting optional
Degree of protection (IP)
IP30
Number of poles
4
Complete device with protection unit
Position of connection for main current circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Motor drive integrated
Type of control element
Push button
With under voltage release
Motor drive optional