Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
With integrated under voltage release
No
Rated permanent current Iu
3200A
Integrated earth fault protection
No
Rated voltage
690 - 690V
Adjustment range undelayed short-circuit release
4800.0 - 48000A
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
Yes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Overload release current setting
1280.0 - 3200A
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
Type of control element
Push button
Motor drive optional
Yes
Suitable for DIN rail (top hat rail) mounting
No
Degree of protection (IP)
IP30
Motor drive integrated
No
Number of poles
4
Number of auxiliary contacts as change-over contact
4
Complete device with protection unit
Yes
From same serie
1SDA073154R1 | E4.2V 3200 EKIP TOUCH LI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
With integrated under voltage release
Rated permanent current Iu
3200A
Integrated earth fault protection
Rated voltage
690 .. 690V
Adjustment range undelayed short-circuit release
4800.0 .. 48000A
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Overload release current setting
1280.0 .. 3200A
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Position of connection for main current circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
Type of control element
Push button
Motor drive optional
Suitable for DIN rail (top hat rail) mounting
Degree of protection (IP)
IP30
Motor drive integrated
Number of poles
4
Number of auxiliary contacts as change-over contact
4