Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
No
Rated permanent current Iu
4000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Number of poles
4
Adjustment range undelayed short-circuit release
6000.0 - 60000A
Rated voltage
690 - 690V
With under voltage release
No
Motor drive optional
Yes
DIN rail (top hat rail) mounting optional
No
With switched-off indicator
Yes
Position of connection for main current circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Integrated earth fault protection
No
Complete device with protection unit
Yes
Number of auxiliary contacts as change-over contact
4
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
1600.0 - 4000A
Motor drive integrated
No
Type of control element
Push button
Degree of protection (IP)
IP30
From same serie
1SDA073174R1 | E4.2N 4000 EKIP TOUCH LI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Suitable for DIN rail (top hat rail) mounting
Rated permanent current Iu
4000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
66kA
Number of poles
4
Adjustment range undelayed short-circuit release
6000.0 .. 60000A
Rated voltage
690 .. 690V
With under voltage release
Motor drive optional
DIN rail (top hat rail) mounting optional
With switched-off indicator
Position of connection for main current circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
Integrated earth fault protection
Complete device with protection unit
Number of auxiliary contacts as change-over contact
4
Type of electrical connection of main circuit
Connection at separate chassis part
Overload release current setting
1600.0 .. 4000A
Motor drive integrated
Type of control element
Push button
Degree of protection (IP)
IP30
From same serie