Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
4000A
Rated voltage
690 - 690V
Suitable for DIN rail (top hat rail) mounting
No
Adjustment range short-term delayed short-circuit release
2400.0 - 40000A
Integrated earth fault protection
Yes
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
6000.0 - 60000A
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Type of control element
Push button
Number of auxiliary contacts as normally open contact
0
Device construction
Built-in device slide-in technique (withdrawable)
With switched-off indicator
Yes
Position of connection for main current circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
Overload release current setting
1600.0 - 4000A
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
No
Motor drive optional
Yes
1SDA073197R1 | E4.2H 4000 EKIP G TOUCH LSIG 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
4000A
Rated voltage
690 .. 690V
Suitable for DIN rail (top hat rail) mounting
Adjustment range short-term delayed short-circuit release
2400.0 .. 40000A
Integrated earth fault protection
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
6000.0 .. 60000A
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Type of control element
Push button
Number of auxiliary contacts as normally open contact
0
Device construction
Built-in device slide-in technique (withdrawable)
With switched-off indicator
Position of connection for main current circuit
Connection at separate chassis part
Degree of protection (IP)
IP30
Complete device with protection unit
Overload release current setting
1600.0 .. 4000A
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
Motor drive optional
We use cookies to enhance your experience.