Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Overload release current setting
1600.0 - 4000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Rated permanent current Iu
4000A
Rated voltage
690 - 690V
Adjustment range short-term delayed short-circuit release
2400.0 - 40000A
Adjustment range undelayed short-circuit release
6000.0 - 60000A
Integrated earth fault protection
No
DIN rail (top hat rail) mounting optional
No
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as change-over contact
4
Type of electrical connection of main circuit
Connection at separate chassis part
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
With under voltage release
No
With switched-off indicator
Yes
Type of control element
Push button
Suitable for DIN rail (top hat rail) mounting
No
Degree of protection (IP)
IP30
Motor drive integrated
No
Motor drive optional
Yes
Complete device with protection unit
Yes
From same serie
1SDA073198R1 | E4.2H 4000 EKIP HI-TOUCH LSI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Overload release current setting
1600.0 .. 4000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Rated permanent current Iu
4000A
Rated voltage
690 .. 690V
Adjustment range short-term delayed short-circuit release
2400.0 .. 40000A
Adjustment range undelayed short-circuit release
6000.0 .. 60000A
Integrated earth fault protection
DIN rail (top hat rail) mounting optional
Device construction
Built-in device slide-in technique (withdrawable)
Number of auxiliary contacts as change-over contact
4
Type of electrical connection of main circuit
Connection at separate chassis part
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
With under voltage release
With switched-off indicator
Type of control element
Push button
Suitable for DIN rail (top hat rail) mounting
Degree of protection (IP)
IP30
Motor drive integrated
Motor drive optional