Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
4000A
Overload release current setting
1600.0 - 4000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Suitable for DIN rail (top hat rail) mounting
No
Adjustment range undelayed short-circuit release
6000.0 - 60000A
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
Yes
Number of poles
4
Integrated earth fault protection
Yes
Device construction
Built-in device slide-in technique (withdrawable)
Complete device with protection unit
Yes
Type of control element
Push button
Rated voltage
690 - 690V
Adjustment range short-term delayed short-circuit release
2400.0 - 40000A
Number of auxiliary contacts as change-over contact
4
Position of connection for main current circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
No
Motor drive integrated
No
Degree of protection (IP)
IP30
Motor drive optional
Yes
1SDA073200R1 | E4.2H 4000 EKIP G HI-TOUCH LSIG 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
4000A
Overload release current setting
1600.0 .. 4000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Suitable for DIN rail (top hat rail) mounting
Adjustment range undelayed short-circuit release
6000.0 .. 60000A
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
With switched-off indicator
Number of poles
4
Integrated earth fault protection
Device construction
Built-in device slide-in technique (withdrawable)
Complete device with protection unit
Type of control element
Push button
Rated voltage
690 .. 690V
Adjustment range short-term delayed short-circuit release
2400.0 .. 40000A
Number of auxiliary contacts as change-over contact
4
Position of connection for main current circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
Motor drive integrated
Degree of protection (IP)
IP30
Motor drive optional