Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Suitable for DIN rail (top hat rail) mounting
No
With switched-off indicator
Yes
Rated permanent current Iu
4000A
Adjustment range undelayed short-circuit release
6000.0 - 60000A
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally closed contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Position of connection for main current circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
No
Rated voltage
690 - 690V
Integrated earth fault protection
No
Overload release current setting
1600.0 - 4000A
Number of auxiliary contacts as normally open contact
0
Adjustment range short-term delayed short-circuit release
2400.0 - 40000A
Degree of protection (IP)
IP30
Type of control element
Push button
Motor drive optional
Yes
Number of poles
4
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
Complete device with protection unit
Yes
Motor drive integrated
No
From same serie
1SDA073205R1 | E4.2V 4000 EKIP TOUCH LSI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Suitable for DIN rail (top hat rail) mounting
With switched-off indicator
Rated permanent current Iu
4000A
Adjustment range undelayed short-circuit release
6000.0 .. 60000A
Number of auxiliary contacts as change-over contact
4
Number of auxiliary contacts as normally closed contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Position of connection for main current circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
Rated voltage
690 .. 690V
Integrated earth fault protection
Overload release current setting
1600.0 .. 4000A
Number of auxiliary contacts as normally open contact
0
Adjustment range short-term delayed short-circuit release
2400.0 .. 40000A
Degree of protection (IP)
IP30
Type of control element
Push button
Motor drive optional
Number of poles
4
Device construction
Built-in device slide-in technique (withdrawable)
Type of electrical connection of main circuit
Connection at separate chassis part
Complete device with protection unit
Motor drive integrated
From same serie