Aleta.hr
Main Product Image

1SDA073211R1 | E6.2H 4000 EKIP DIP LI 4P WMP

Code: 1615847

ManufacturerABB
Catalog number1SDA073211R1
EAN code8015644770617

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release- - -A
With integrated under voltage releaseNo
Type of electrical connection of main circuitConnection at separate chassis part
Number of auxiliary contacts as normally open contact0
Suitable for DIN rail (top hat rail) mountingNo
Number of auxiliary contacts as normally closed contact0
Overload release current setting1600.0 - 4000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100kA
Rated permanent current Iu4000A
Device constructionBuilt-in device slide-in technique (withdrawable)
With switched-off indicatorYes
Type of control elementPush button
Number of poles4
Motor drive integratedNo
Position of connection for main current circuitConnection at separate chassis part
Integrated earth fault protectionNo
Number of auxiliary contacts as change-over contact4
Degree of protection (IP)IP30
DIN rail (top hat rail) mounting optionalNo
Complete device with protection unitYes
Adjustment range undelayed short-circuit release6000.0 - 60000A
Motor drive optionalYes
Rated voltage690 - 690V
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA073211R1 | E6.2H 4000 EKIP DIP LI 4P WMP

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Adjustment range short-term delayed short-circuit release

- .. -A

With integrated under voltage release

Type of electrical connection of main circuit

Connection at separate chassis part

Number of auxiliary contacts as normally open contact

0

Suitable for DIN rail (top hat rail) mounting

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

1600.0 .. 4000A

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

Rated permanent current Iu

4000A

Device construction

Built-in device slide-in technique (withdrawable)

With switched-off indicator

Type of control element

Push button

Number of poles

4

Motor drive integrated

Position of connection for main current circuit

Connection at separate chassis part

Integrated earth fault protection

Number of auxiliary contacts as change-over contact

4

Degree of protection (IP)

IP30

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Adjustment range undelayed short-circuit release

6000.0 .. 60000A

Motor drive optional

Rated voltage

690 .. 690V

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.