Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Suitable for DIN rail (top hat rail) mounting
No
Integrated earth fault protection
Yes
Device construction
Built-in device slide-in technique (withdrawable)
Rated permanent current Iu
5000A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
No
Adjustment range short-term delayed short-circuit release
3000.0 - 50000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Overload release current setting
2000.0 - 5000A
Adjustment range undelayed short-circuit release
7500.0 - 75000A
Rated voltage
690 - 690V
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
No
Number of poles
4
With switched-off indicator
Yes
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Yes
Complete device with protection unit
Yes
Type of control element
Push button
Degree of protection (IP)
IP30
From same serie
1SDA073247R1 | E6.2H 5000 EKIP G TOUCH LSIG 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Suitable for DIN rail (top hat rail) mounting
Integrated earth fault protection
Device construction
Built-in device slide-in technique (withdrawable)
Rated permanent current Iu
5000A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
DIN rail (top hat rail) mounting optional
Adjustment range short-term delayed short-circuit release
3000.0 .. 50000A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Overload release current setting
2000.0 .. 5000A
Adjustment range undelayed short-circuit release
7500.0 .. 75000A
Rated voltage
690 .. 690V
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Motor drive integrated
Number of poles
4
With switched-off indicator
Position of connection for main current circuit
Connection at separate chassis part
Motor drive optional
Complete device with protection unit
Type of control element
Push button
Degree of protection (IP)
IP30