Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optional
No
Suitable for DIN rail (top hat rail) mounting
No
With switched-off indicator
Yes
Number of auxiliary contacts as change-over contact
4
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Rated voltage
690 - 690V
Motor drive integrated
No
Overload release current setting
2000.0 - 5000A
With under voltage release
No
Number of poles
4
Integrated earth fault protection
No
Motor drive optional
Yes
Complete device with protection unit
Yes
Adjustment range undelayed short-circuit release
7500.0 - 75000A
Degree of protection (IP)
IP30
Adjustment range short-term delayed short-circuit release
3000.0 - 50000A
Rated permanent current Iu
5000A
From same serie
1SDA073248R1 | E6.2H 5000 EKIP HI-TOUCH LSI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Type of electrical connection of main circuit
Connection at separate chassis part
Device construction
Built-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optional
Suitable for DIN rail (top hat rail) mounting
With switched-off indicator
Number of auxiliary contacts as change-over contact
4
Position of connection for main current circuit
Connection at separate chassis part
Type of control element
Push button
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Rated voltage
690 .. 690V
Motor drive integrated
Overload release current setting
2000.0 .. 5000A
With under voltage release
Number of poles
4
Integrated earth fault protection
Motor drive optional
Complete device with protection unit
Adjustment range undelayed short-circuit release
7500.0 .. 75000A
Degree of protection (IP)
IP30
Adjustment range short-term delayed short-circuit release
3000.0 .. 50000A
Rated permanent current Iu
5000A
From same serie