Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- - -A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Rated permanent current Iu
6300A
Overload release current setting
2520.0 - 6300A
Rated voltage
690 - 690V
Integrated earth fault protection
No
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
No
DIN rail (top hat rail) mounting optional
No
Number of poles
4
Number of auxiliary contacts as change-over contact
4
Adjustment range undelayed short-circuit release
9450.0 - 94500A
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Yes
Complete device with protection unit
Yes
Degree of protection (IP)
IP30
Motor drive optional
Yes
Type of control element
Push button
Motor drive integrated
No
Device construction
Built-in device slide-in technique (withdrawable)
With under voltage release
No
From same serie
1SDA073284R1 | E6.2V 6300 EKIP TOUCH LI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
Adjustment range short-term delayed short-circuit release
- .. -A
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Rated permanent current Iu
6300A
Overload release current setting
2520.0 .. 6300A
Rated voltage
690 .. 690V
Integrated earth fault protection
Type of electrical connection of main circuit
Connection at separate chassis part
Suitable for DIN rail (top hat rail) mounting
DIN rail (top hat rail) mounting optional
Number of poles
4
Number of auxiliary contacts as change-over contact
4
Adjustment range undelayed short-circuit release
9450.0 .. 94500A
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Complete device with protection unit
Degree of protection (IP)
IP30
Motor drive optional
Type of control element
Push button
Motor drive integrated
Device construction
Built-in device slide-in technique (withdrawable)
With under voltage release
From same serie