Aleta.hr

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact0
With integrated under voltage releaseNo
Number of auxiliary contacts as normally closed contact0
Overload release current setting2520.0 - 6300A
Type of electrical connection of main circuitConnection at separate chassis part
Type of control elementPush button
Number of auxiliary contacts as change-over contact4
Degree of protection (IP)IP30
Motor drive integratedNo
Adjustment range short-term delayed short-circuit release3780.0 - 63000A
Integrated earth fault protectionYes
Complete device with protection unitYes
Adjustment range undelayed short-circuit release9450.0 - 94500A
Suitable for DIN rail (top hat rail) mountingNo
Device constructionBuilt-in device slide-in technique (withdrawable)
Position of connection for main current circuitConnection at separate chassis part
DIN rail (top hat rail) mounting optionalNo
With switched-off indicatorYes
Motor drive optionalYes
Rated permanent current Iu6300A
Number of poles4
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz150kA
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA073289R1 | E6.2V 6300 EKIP HI-TOUCH LSIG 4P WMP

Main Product Image

Why Register?

  • View wholesale prices with discounts
  • Real-time stock availability
  • Access invoices and dispatch notes
  • Order history and frequently ordered items
  • Exclusive B2B offers

and much more...

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

Number of auxiliary contacts as normally open contact

0

With integrated under voltage release

Number of auxiliary contacts as normally closed contact

0

Overload release current setting

2520.0 .. 6300A

Type of electrical connection of main circuit

Connection at separate chassis part

Type of control element

Push button

Number of auxiliary contacts as change-over contact

4

Degree of protection (IP)

IP30

Motor drive integrated

Adjustment range short-term delayed short-circuit release

3780.0 .. 63000A

Integrated earth fault protection

Complete device with protection unit

Adjustment range undelayed short-circuit release

9450.0 .. 94500A

Suitable for DIN rail (top hat rail) mounting

Device construction

Built-in device slide-in technique (withdrawable)

Position of connection for main current circuit

Connection at separate chassis part

DIN rail (top hat rail) mounting optional

With switched-off indicator

Motor drive optional

Rated permanent current Iu

6300A

Number of poles

4

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

150kA

VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.