1SDA073310R1 | E6.2H/F 4000 EKIP G HI-TOUCH LSIG 4P WMP

Code: 1615916

ManufacturerABB
Catalog number1SDA073310R1
EAN code8015644771607

















Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage releaseNo
Rated permanent current Iu4000A
Rated voltage690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz100kA
Adjustment range short-term delayed short-circuit release2400.0 - 40000A
Overload release current setting1600.0 - 4000A
Integrated earth fault protectionYes
Type of electrical connection of main circuitConnection at separate chassis part
Device constructionBuilt-in device slide-in technique (withdrawable)
DIN rail (top hat rail) mounting optionalNo
Number of auxiliary contacts as normally open contact0
Number of auxiliary contacts as change-over contact4
Suitable for DIN rail (top hat rail) mountingNo
Adjustment range undelayed short-circuit release6000.0 - 60000A
Number of auxiliary contacts as normally closed contact0
Position of connection for main current circuitConnection at separate chassis part
With switched-off indicatorYes
Type of control elementPush button
Number of poles4
Motor drive integratedNo
Degree of protection (IP)IP30
Complete device with protection unitYes
Motor drive optionalYes
*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user

1SDA073310R1 | E6.2H/F 4000 EKIP G HI-TOUCH LSIG 4P WMP

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • ABB

Technical specifications

With integrated under voltage release

Rated permanent current Iu

4000A

Rated voltage

690 .. 690V

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

100kA

Adjustment range short-term delayed short-circuit release

2400.0 .. 40000A

Overload release current setting

1600.0 .. 4000A

Integrated earth fault protection

Type of electrical connection of main circuit

Connection at separate chassis part

Device construction

Built-in device slide-in technique (withdrawable)

DIN rail (top hat rail) mounting optional

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as change-over contact

4

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

6000.0 .. 60000A

Number of auxiliary contacts as normally closed contact

0

Position of connection for main current circuit

Connection at separate chassis part

With switched-off indicator

Type of control element

Push button

Number of poles

4

Motor drive integrated

Degree of protection (IP)

IP30

Complete device with protection unit

Motor drive optional