Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
4000A
Adjustment range short-term delayed short-circuit release
2400.0 - 40000A
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
6000.0 - 60000A
Suitable for DIN rail (top hat rail) mounting
No
Integrated earth fault protection
No
Number of auxiliary contacts as change-over contact
4
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Device construction
Built-in device slide-in technique (withdrawable)
Overload release current setting
1600.0 - 4000A
With switched-off indicator
Yes
Number of poles
4
Position of connection for main current circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally open contact
0
Type of control element
Push button
Degree of protection (IP)
IP30
Motor drive integrated
No
Motor drive optional
Yes
Complete device with protection unit
Yes
Number of auxiliary contacts as normally closed contact
0
Rated voltage
690 - 690V
From same serie
1SDA073312R1 | E6.2V/F 4000 EKIP DIP LSI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
4000A
Adjustment range short-term delayed short-circuit release
2400.0 .. 40000A
Type of electrical connection of main circuit
Connection at separate chassis part
Adjustment range undelayed short-circuit release
6000.0 .. 60000A
Suitable for DIN rail (top hat rail) mounting
Integrated earth fault protection
Number of auxiliary contacts as change-over contact
4
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Device construction
Built-in device slide-in technique (withdrawable)
Overload release current setting
1600.0 .. 4000A
With switched-off indicator
Number of poles
4
Position of connection for main current circuit
Connection at separate chassis part
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally open contact
0
Type of control element
Push button
Degree of protection (IP)
IP30
Motor drive integrated
Motor drive optional
Complete device with protection unit
Number of auxiliary contacts as normally closed contact
0
Rated voltage
690 .. 690V
From same serie