Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
5000A
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
No
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Yes
Integrated earth fault protection
Yes
Degree of protection (IP)
IP30
Complete device with protection unit
Yes
Type of control element
Push button
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Suitable for DIN rail (top hat rail) mounting
No
Overload release current setting
2000.0 - 5000A
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 - 690V
Adjustment range undelayed short-circuit release
7500.0 - 75000A
Adjustment range short-term delayed short-circuit release
3000.0 - 50000A
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Motor drive optional
Yes
Motor drive integrated
No
Type of electrical connection of main circuit
Connection at separate chassis part
From same serie
1SDA073350R1 | E6.2V/F 5000 EKIP G HI-TOUCH LSIG 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
5000A
Number of auxiliary contacts as change-over contact
4
DIN rail (top hat rail) mounting optional
Number of auxiliary contacts as normally open contact
0
Position of connection for main current circuit
Connection at separate chassis part
With switched-off indicator
Integrated earth fault protection
Degree of protection (IP)
IP30
Complete device with protection unit
Type of control element
Push button
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
Suitable for DIN rail (top hat rail) mounting
Overload release current setting
2000.0 .. 5000A
Device construction
Built-in device slide-in technique (withdrawable)
Rated voltage
690 .. 690V
Adjustment range undelayed short-circuit release
7500.0 .. 75000A
Adjustment range short-term delayed short-circuit release
3000.0 .. 50000A
Number of auxiliary contacts as normally closed contact
0
Number of poles
4
Motor drive optional
Motor drive integrated
Type of electrical connection of main circuit
Connection at separate chassis part
From same serie