Technical specifications
With integrated under voltage release
No
Rated permanent current Iu
6300A
Rated voltage
690 - 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Adjustment range short-term delayed short-circuit release
3780.0 - 63000A
Adjustment range undelayed short-circuit release
9450.0 - 94500A
Suitable for DIN rail (top hat rail) mounting
No
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
Motor drive integrated
No
Type of control element
Push button
With switched-off indicator
Yes
Motor drive optional
Yes
Device construction
Built-in device slide-in technique (withdrawable)
Complete device with protection unit
Yes
Degree of protection (IP)
IP30
Integrated earth fault protection
No
DIN rail (top hat rail) mounting optional
No
Overload release current setting
2520.0 - 6300A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0
From same serie
1SDA073368R1 | E6.2H/F 6300 EKIP HI-TOUCH LSI 4P WMP

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- ABB
Technical specifications
With integrated under voltage release
Rated permanent current Iu
6300A
Rated voltage
690 .. 690V
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
100kA
Adjustment range short-term delayed short-circuit release
3780.0 .. 63000A
Adjustment range undelayed short-circuit release
9450.0 .. 94500A
Suitable for DIN rail (top hat rail) mounting
Type of electrical connection of main circuit
Connection at separate chassis part
Number of auxiliary contacts as change-over contact
4
Position of connection for main current circuit
Connection at separate chassis part
Number of poles
4
Motor drive integrated
Type of control element
Push button
With switched-off indicator
Motor drive optional
Device construction
Built-in device slide-in technique (withdrawable)
Complete device with protection unit
Degree of protection (IP)
IP30
Integrated earth fault protection
DIN rail (top hat rail) mounting optional
Overload release current setting
2520.0 .. 6300A
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as normally closed contact
0