Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- ABB
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Conditioned rated short-circuit current Iq
-kA
Rated operation power at AC-23, 400 V
-kW
Interlockable
No
Switching power at 400 V
-kW
Number of switches
0
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Version as main switch
Yes
Version as maintenance-/service switch
No
Rated short-time withstand current lcw
50kA
Rated operating voltage
690 - 690V
Version as emergency stop installation
No
Rated permanent current at AC-23, 400 V
630A
Version as safety switch
No
Version as reversing switch
No
Rated permanent current Iu
630A
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-21, 400 V
630A
Suitable for floor mounting
No
Voltage release optional
Yes
Number of poles
3
Motor drive integrated
No
Motor drive optional
Yes
Suitable for distribution board installation
Yes
Suitable for front mounting 4-hole
No
Suitable for intermediate mounting
No
Degree of protection (IP), front side
IP30
Type of control element
Push button
Device construction
Built-in device fixed built-in technique
Type of electrical connection of main circuit
Bolt connection
Degree of protection (NEMA)
Other
Suitable for front mounting centre
No
Colour control element
Other
From same serie
1SDA073393R1 | E1.2N/MS 630 3P F F

Details
- Low-voltage industrial components
- Switch disconnector
- 1 KOM
- ABB
Technical specifications
Rated operation power at AC-3, 400 V
-kW
Conditioned rated short-circuit current Iq
-kA
Rated operation power at AC-23, 400 V
-kW
Interlockable
Switching power at 400 V
-kW
Number of switches
0
Number of auxiliary contacts as normally closed contact
0
Number of auxiliary contacts as normally open contact
0
Number of auxiliary contacts as change-over contact
0
Version as main switch
Version as maintenance-/service switch
Rated short-time withstand current lcw
50kA
Rated operating voltage
690 .. 690V
Version as emergency stop installation
Rated permanent current at AC-23, 400 V
630A
Version as safety switch
Version as reversing switch
Rated permanent current Iu
630A
Max. rated operation voltage Ue AC
690V
Rated permanent current at AC-21, 400 V
630A
Suitable for floor mounting
Voltage release optional
Number of poles
3
Motor drive integrated
Motor drive optional
Suitable for distribution board installation
Suitable for front mounting 4-hole
Suitable for intermediate mounting
Degree of protection (IP), front side
IP30
Type of control element
Push button
Device construction
Built-in device fixed built-in technique
Type of electrical connection of main circuit
Bolt connection
Degree of protection (NEMA)
Other
Suitable for front mounting centre
Colour control element
Other
From same serie
We use cookies to enhance your experience.